Agilent BioTek 405 TS Touch Microplate Washer
The BioTek 405 TS washer has an excellent reputation in life science research for outstanding results in many applications.
Additional Details:
Weight:
13.50000kg
Specification
Assays | ELISA, Cell-based assays, Magnetic and polystyrene bead, Multiplex assays, Bead-based ELISAs, Filtration-to-waste processes (model dependent),ELISA, Cell-based assays, Magnetic and polystyrene bead, Multiplex assays, Bead-based ELISAs, Filtration-to-waste processes (model dependent) |
---|---|
Assays | ELISA, Cell-based assays, Magnetic and polystyrene bead, Multiplex assays, Bead-based ELISAs, Filtration-to-waste processes (model dependent),ELISA, Cell-based assays, Magnetic and polystyrene bead, Multiplex assays, Bead-based ELISAs, Filtration-to-waste processes (model dependent) |
Certifications/Compliance | CE and TUV marked. RoHS compliant.,CE and TUV marked. RoHS compliant. |
Certifications/Compliance | CE and TUV marked. RoHS compliant.,CE and TUV marked. RoHS compliant. |
Connections | USB (2),USB (2) |
Connections | USB (2),USB (2) |
Bottles | Optional (4 or 10 L),Optional (4 or 10 L) |
Bottles | Optional (4 or 10 L),Optional (4 or 10 L) |
Precision | <3% CV: 300 μL/well - 96-well washing; <4% CV: 80 μL/well - 384-well washing (plate types are model dependent),<3% CV: 300 μL/well - 96-well washing; <4% CV: 80 μL/well - 384-well washing (plate types are model dependent) |
Precision | <3% CV: 300 μL/well - 96-well washing; <4% CV: 80 μL/well - 384-well washing (plate types are model dependent),<3% CV: 300 μL/well - 96-well washing; <4% CV: 80 μL/well - 384-well washing (plate types are model dependent) |
Dispense Volume | 25 to 3000 μL/well (192-pin manifold); 50 to 3000 μL/well (96-pin manifold),25 to 3000 μL/well (with 192-pin manifold); 50 to 3000 μL/well (with 96-pin manifold) |
Dispense Volume | 25 to 3000 μL/well (192-pin manifold); 50 to 3000 μL/well (96-pin manifold),25 to 3000 μL/well (with 192-pin manifold); 50 to 3000 μL/well (with 96-pin manifold) |
Plate Type | 96- and 384-well, Low Profile and Standard, Solid and Filter Bottom (Option) Plates,96- and 384-well, Low Profile and Standard, Solid and Filter Bottom (Option) Plates |
Plate Type | 96- and 384-well, Low Profile and Standard, Solid and Filter Bottom (Option) Plates,96- and 384-well, Low Profile and Standard, Solid and Filter Bottom (Option) Plates |
Residual Volume | ≤2 μL/well,≤2 μL/well |
Residual Volume | ≤2 μL/well,≤2 μL/well |
Washing Speed |
96-wells: 300 μL/well, 3 cycles: <30 s; 384-wells: 100 μL/well, 3 cycles: <80 s; 384-wells: 400 μL/well, 1 cycle: <20 s (plate types are model dependent) ,96-wells: 300 μL/well, 3 cycles: <30 s; 384-wells: 100 μL/well, 3 cycles: <80 s; 384-wells: 400 μL/well, 1 cycle: <20 s (plate types are model dependent)
|
Washing Speed |
96-wells: 300 μL/well, 3 cycles: <30 s; 384-wells: 100 μL/well, 3 cycles: <80 s; 384-wells: 400 μL/well, 1 cycle: <20 s (plate types are model dependent) ,96-wells: 300 μL/well, 3 cycles: <30 s; 384-wells: 100 μL/well, 3 cycles: <80 s; 384-wells: 400 μL/well, 1 cycle: <20 s (plate types are model dependent)
|
Soak Time | Programmable in minutes and seconds, up to 60 min.,Programmable in minutes and seconds, up to 60 min. |
Soak Time | Programmable in minutes and seconds, up to 60 min.,Programmable in minutes and seconds, up to 60 min. |
Type | Microplate Washer,Microplate Washer |
Type | Microplate Washer,Microplate Washer |
Weight (Metric) | With internal buffer switching - 16.5 kg; Without - 13.5 kg,With internal buffer switching - 16.5 kg; Without - 13.5 kg |
Weight (Metric) | With internal buffer switching - 16.5 kg; Without - 13.5 kg,With internal buffer switching - 16.5 kg; Without - 13.5 kg |
Wash Cycles | 1 to 250 |
Wash Volume | 25 to 3000 μL/well,25 to 3000 μL/well |
Wash Volume | 25 to 3000 μL/well,25 to 3000 μL/well |
Display | LED |
Flow Rate | High to Low Flow; Optimized rates for cell assays (model dependent),High to Low Flow; Optimized rates for cell assays (model dependent) |
Flow Rate | High to Low Flow; Optimized rates for cell assays (model dependent),High to Low Flow; Optimized rates for cell assays (model dependent) |
Fluid Delivery Type | Internal positive displacement pump |
For Use With (Application) | ELISA; MSD assays; HCS immune cytochemistry; FLIPR Ca2+ flux; Cell-based assays; Magnetic and polystyrene bead processing - e.g., gene expression assays, cytokine assays; ELISPOT assays (model dependent),ELISA; MSD assays; HCS immune cytochemistry; FLIPR Ca2+ flux; Cell-based assays; Magnetic and polystyrene bead processing - e.g., gene expression assays, cytokine assays; ELISPOT assays (model dependent) |
For Use With (Application) | ELISA; MSD assays; HCS immune cytochemistry; FLIPR Ca2+ flux; Cell-based assays; Magnetic and polystyrene bead processing - e.g., gene expression assays, cytokine assays; ELISPOT assays (model dependent),ELISA; MSD assays; HCS immune cytochemistry; FLIPR Ca2+ flux; Cell-based assays; Magnetic and polystyrene bead processing - e.g., gene expression assays, cytokine assays; ELISPOT assays (model dependent) |
Frequency | 50/60 Hz,50/60 Hz |
Frequency | 50/60 Hz,50/60 Hz |
Model | 405TSRS,405TSRS |
Model | 405TSRS,405TSRS |
Includes | 96-well microplate washing, Ultrasonic Advantage |
Width (English) | 14 in.,14 in. |
Width (English) | 14 in.,14 in. |
Width (Metric) | 35.6 cm |
Height (English) | 10 in.,10 in. |
Height (English) | 10 in.,10 in. |
Height (Metric) | 25.4 cm,25.4 cm |
Height (Metric) | 25.4 cm,25.4 cm |
Depth (English) | 17 in.,17 in. |
Depth (English) | 17 in.,17 in. |
Depth (Metric) | 43.2 cm,43.2 cm |
Depth (Metric) | 43.2 cm,43.2 cm |
Automation Interface | High Resolution LED Backlit Touch Screen,High Resolution LED Backlit Touch Screen |
Automation Interface | High Resolution LED Backlit Touch Screen,High Resolution LED Backlit Touch Screen |
Weight (English) | With internal buffer switching - 36 lb.; Without - 30 lb. |
Voltage | 100/240 V |